服務(wù)熱線電話
400-6188-756
多槽手動超聲波清洗機的使用
來源:http://ckjy.net.cn/ 時間: 2023-10-27 瀏覽次數(shù): 0
多槽手動超聲波清洗機的使用方法如下:
The usage method of the multi slot manual ultrasonic cleaning machine is as follows:
將發(fā)生器與清洗槽連接電纜接好。
Connect the cable connecting the generator to the cleaning tank.
將槽內(nèi)注入選用的清洗液。
Inject the selected cleaning solution into the tank.
將發(fā)生器接入220V±10% 50赫茲交流電源。
Connect the generator to a 220V ± 10% 50Hz AC power supply.
打開發(fā)生器電源開關(guān),電源指示燈亮(此時槽內(nèi)液體開始振動空化)。
Turn on the power switch of the generator, and the power indicator light will be on (at this point, the liquid in the tank will start to vibrate and cavitate).
使用多槽手動超聲波清洗機時,應(yīng)注意事項包括:
When using a multi slot manual ultrasonic cleaning machine, precautions include:
設(shè)備必須放在通風(fēng)、干燥的區(qū)域,發(fā)生器后側(cè)的風(fēng)扇孔應(yīng)定期清潔。發(fā)生器四面留有通風(fēng)口,以使氣流暢通無阻。
The equipment must be placed in a ventilated and dry area, and the fan holes behind the generator should be cleaned regularly. There are ventilation openings on all sides of the generator to ensure smooth airflow.
超聲波清洗槽必須放入液體后才能開機工作,低水位高度>100mm(底振式)且水平放置,換能器在側(cè)面時,為清洗槽槽沿100mm處,如在空氣狀態(tài)開機會損壞機器。
The ultrasonic cleaning tank must be filled with liquid before starting up and working. The low water level height is greater than 100mm (bottom vibration type) and placed horizontally. When the transducer is on the si
de, it is necessary to clean the tank along the 100mm edge. If starting up in air, it will damage the machine.
de, it is necessary to clean the tank along the 100mm edge. If starting up in air, it will damage the machine.
當(dāng)清洗缸體溫度為常溫時,切勿將高溫液體直接注入缸內(nèi),以免導(dǎo)致?lián)Q能器松動而影響機器正常使用。
When the cleaning temperature of the cylinder block is at room temperature, do not directly inject high-temperature liquid into the cylinder to avoid loosening the transducer and affecting the normal use of the machine.
定期檢查換能器,切勿使其變潮及撞擊,以免造成不必要的損失。使用完畢后,應(yīng)關(guān)閉總電源。關(guān)機后不要立刻重新開機,間隙時間應(yīng)在1分鐘以上。
Regularly inspect the transducer and do not let it become damp or collide to avoid unnecessary losses. After use, the main power should be turned off. Do not restart immediately after shutting down, the gap time should be at least 1 minute.
以上是使用多槽手動超聲波清洗機的步驟和注意事項,供您參考,建議根據(jù)實際情況加以調(diào)整。
The above are the steps and precautions for using a multi slot manual ultrasonic cleaning machine for your reference. It is recommended to make adjustments according to the actual situation.
相關(guān)產(chǎn)品
相關(guān)文章
-
超聲波清洗和普通清洗有什么區(qū)別 2024-12-23
-
超聲波清洗機10大忌 2024-12-14
-
全自動超聲波清洗機需要定期維護嗎? 2024-12-13
-
高壓去毛刺清洗機的高壓水流介紹 2024-12-10
-
超聲波清洗機相關(guān)常見問題及解答 2024-12-07
-
分體式超聲波清洗機與普通的有什么區(qū)別? 2024-12-05
-
碳氫清洗機對于環(huán)保工業(yè)的清晰要點 2024-12-03
-
噴淋清洗機:壓力過大怎么調(diào)整? 2024-11-25
-
通過式噴淋清洗機:為什么洗不干凈? 2024-11-22
-
高壓去毛刺清洗機:遇見故障莫慌張,依次排查按文章 2024-11-21